SPECTRUM ANALYZER
Frequency Range: 400 kHz to 1 GHz
Dispersion:
Selectable from keypad, as follows:
200 kHz window - (20 kHz per division)
500 kHz window - (50 kHz per division)
1 MHz window - (100 kHz per division)
2 MHz window - (200 kHz per division)
5 MHz window - (500 kHz per division)
10 MHz window - (1 MHz per division)
20 MHz window - (2 MHz per division)*
50 MHz window - (5 MHz per division)*
100 MHz window - (10 MHz
per division)*
Dynamic Range: 60 dB
Bandwidth:
Automatically selected:
6 kHz - (100 kHz per division & below)
30 kHz - (200 kHz per division & above)
Display Range: +50 to -95 dBm
Modes: Freeze, Max Hold, Peak Hold,
Average*
Markers: Delta or Absolute Level and Frequency*
SIGNAL STRENGTH
INDICATOR
Range: 400 KHz to 1 GHz
Accuracy: ±4 dB, >3 MHz
Sensitivity: -100 dBm (antenna port rating)
WATTMETER
(RF I/O PORT)
Frequency Range: 400 KHz to 1 GHz
Measurement Range: .1 watt to 125 watts
Input Impedance: 50 ohms with maximum VSWR of 1.5:1
Accuracy: ±10%, >3 MHz
Protection: Over temperature alarms
TRACKING GENERATOR*
Frequency Range: 400 kHz to 1 GHz
Tracking Display
Sweep Range:
200 kHz window - (20 kHz per division)
500 kHz window - (50 kHz per division)
1 MHz window - (100 kHz per division)
2 MHz window - (200 kHz per division)
5 MHz window - (500 kHz per division)
10 MHz window - (1 MHz per division)
20 MHz window - (2 MHz per division)
50 MHz window - (5 MHz per division)
Display Range: 0 to -80 dBm
CABLE FAULT*
Method: Standing Wave Analysis
Measure: Fault distance, cable length
Reading: Feet and meters
Accuracy: ±10%
Metering & Measurement (Cont.)
OSCILLOSCOPE
Display Size: 6.4 in (17 cm) diagonal
Frequency
Response: 0 to 50 kHz
Vertical Input
Ranges: Selectable per the following:
10 mV, 20 mV, 50 mV, 100 mV, 200 mV,
500 mV, 1v, 2v, 5v, 10v per division
Accuracy: 5% of full scale all ranges
Sweep Ranges: Selectable per the following:
20 usec, 50 usec, 100 usec, 200 usec,
500 usec, 1 msec, 2 msec, 5 msec,
10 msec, 20 msec, 50 msec, 100 msec,
200 msec, 500 msec, 1 sec per division
Trigger: Automatic, normal, and single sweep
Markers: Delta Voltage, Delta Frequency,
Delta Period*
DIGITAL VOLTMETER
Meter Type: RMS
Frequency Range: DC plus AC of 50 Hz to 20 kHz
DC Voltage Ranges: 1.0 V, 10.0 V, 100.0 V full scale
Accuracy: 1% full scale ±1 least significant digit
AC Voltage Ranges: 1.0 V, 10.0 V, 70.0 V full scale
Accuracy: 5% full scale ±1 least significant digit
Freq. Response: 3 dB end points @ 50 Hz and 20 kHz
FREQUENCY COUNTER
Frequency Range: 5 Hz to 500 kHz plus Auto Tune
Period Counter
Range: 5 Hz to 20 kHz
Input Level: 0.1 v RMS minimum input level
Resolution: 0.1 Hz, 1 Hz and 10 Hz
varying by frequency range
Auto Tune: Monitor mode, 20 MHz to 1 GHz, unit
will scan and find signals greater than
-30 dBm
Accuracy: See TIME BASE
SINAD/DISTORTION
METER
Input Level: 0.1 V to 10 V RMS
SINAD Accuracy: ±1 dB at 12 dB SINAD
Distortion Range: 1% to 20%
Distortion Accuracy: ±0.5% of distortion or ±10% of reading
whichever is greater
Optional: C-Message Filter; CCITT Filter
w/ 600 ohm switchable load
TONE SEQUENCE
DECODE
Modulation types: PRIVATE LINE, DIGITAL PRIVATE
LINE, Single Tone, DTMF, Two-Tone
Paging, 5/6 Tone Paging, International
Select V, 20 Tone General Sequence.
Frequency Accuracy: ±3% from 300 Hz to 3 kHz
Duration Accuracy: ±12 msec for tones greater than
30 msec and 300 Hz
RS232 PORT
Bi-directional port provided with capability to respond to serial
input command vocabulary to activate standard functions and
return measured results. Baud rates to 115.2 Kbps with selectable
start, stop and parity bits.
TIME BASE: Aging .5 ppm/yr,
Temperature .05 ppm
14
SECURENET (Optional Feature)
Voice Testing: SECURENET compatible vocoder for
both generator and receiver provides
functional voice testing capability via
internal speaker and microphone
accessory. Scope display of voice
waveform can also be selected.
Encryption Capability: DVP-XL, DES, DES-XL, DVI-XL
For each of these algorithms, the unit
can emulate an AX, BX or CX-type key
loader to load test keys to a compatible
radio. It can accept actual keys from
Motorola external key loaders. A single
side connector is provided for key loading.
End of Message Test: The signaling tone that terminates
a SECURENET transmission can be
detected and displayed to the operator.
BER Capability: Free running, unframed V.52 pseudo
random non-encrypted sequence.
Measurement range from 0 to 20%
bit errors.
Printer/Remote
Control: RS-232 DB25 (female)
Color Monitor: Standard 15 pin VGA
AC: 100 to 130 VRMS or 200 to 260 VRMS
@ 50 Hz to 440 Hz
DC: +11 to +16 VDC (10A Fused)
Battery Option: 13.6 V, 50 minutes typical
Dimensions: 8.5” high x 16” wide x 17” deep
(21.6 cm x 40.7 cm wide x 43.2 cm)
excluding accessories, battery pack
and cover
Weight: 28.5 lbs., base unit without cover, options
or accessories
Temperature: 0° C to +50° C (operating)
-40° C to +85° C (storage)
INTERFACE PORTS
POWER & ENVIRONMENT
METERING & MEASUREMENT
*optional in R2600 and R2625; standard in R2670